Silicon Remind DocsOpen Remind ↗
SILICON REMIND / DOCUMENTATION

Build an interface with Silicon Remind#

Add remind to the interface’s app IDs in Silicon Accounts. After sign-in, take apps["remind"].access_token from the Accounts result. If access was declined or that entry is missing, offer sign-in again before opening Remind. Use the following API from a browser or your own backend. It serves the same reminder data and permissions as the Remind website.

Connection Value
Production base https://api.remind.teamofsilicons.com/api/v2
Authentication Authorization: Bearer <Remind access token>
Contract X-Remind-API-Version: 2. Discover versions at GET https://api.remind.teamofsilicons.com/api/versions.
JSON and browser access Set Content-Type: application/json when sending JSON. Cross-origin requests support preflight and explicit bearer authentication with credentials: "omit".
Full request and response schemas OpenAPI 3.1 and the HTTP reference

From sign-in to the first reminder#

This browser example uses the sign-in result already held by the interface. Keep tokens out of URLs, logs and storage shared with other origins. The example schedules a single reminder at the next 09:00 in Kolkata. Keep the generated creation key with the submitted form until the outcome is known.

const base = 'https://api.remind.teamofsilicons.com/api/v2';
const token = signIn.apps.remind.access_token;
async function remind(path, { method = 'GET', body, key } = {}) {
  const headers = { Authorization: `Bearer ${token}`, 'X-Remind-API-Version': '2' };
  if (body !== undefined) headers['Content-Type'] = 'application/json';
  if (key) headers['Idempotency-Key'] = key;
  const res = await fetch(base + path, {
    method, headers, credentials: 'omit', body: JSON.stringify(body),
  });
  if (res.status === 204) return;
  const result = await res.json();
  if (!res.ok) throw Object.assign(new Error(result.error.message), {
    status: res.status, code: result.error.code, requestId: res.headers.get('X-Request-ID'),
  });
  return result;
}
const me = await remind('/auth/me');
if (me.can_manage_reminders) {
  const key = crypto.randomUUID();
  const schedule = await remind('/schedules', { method: 'POST', key, body: {
    text: 'Review the overnight build', kind: 'one_time', cron: '0 9 * * *', timezone: 'Asia/Kolkata',
  }});
  const history = await remind(`/schedules/${schedule.id}/executions`);
}

Creation returns 201 with id, text, kind, cron, timezone, status, next_run_at and owner metadata. Before the first occurrence, history returns {"items":[],"next_cursor":null}. After the worker delivers it, an execution can look like this.

{"items":[{"id":"019a0000-0000-7000-8000-000000000002","schedule_id":"019a0000-0000-7000-8000-000000000001","scheduled_for":"2026-11-19T03:30:00Z","attempted_at":"2026-11-19T03:30:02Z","delivered_at":"2026-11-19T03:30:03Z","status":"delivered","ting_status":"accepted","webhook_status":"none","hook_event_id":null,"failure_reason":null}],"next_cursor":null}

Operations and permissions#

Paths below are relative to the production base. Use GET /auth/me for capabilities, GET /silicons for visible owners, and their immutable Accounts UUIDs for selection. An owning Silicon can create and change reminders. Its custodian, sibling Silicons, and explicitly granted viewers can read them. Use the viewer and allow-list endpoints to manage explicit sharing.

Frontend feature API operations Who can use it
Account and visible Silicons GET /auth/me, GET /silicons Signed-in Carbon or Silicon
Current or archived reminders GET /schedules?section=current or archived, GET /schedules/{id}, GET /schedules/{id}/executions Caller with read access to the owner
Create or edit, pause or resume, archive POST /schedules, PATCH /schedules/{id}, PATCH /schedules for a batch, DELETE /schedules/{id} Owning Silicon
Ting setup GET /ting, PUT /ting Calling Silicon
Optional webhook copies GET or POST /webhooks, DELETE /webhooks/{subscription_id}. Compatibility routes support GET, PUT and DELETE /webhook. Silicon manages its own endpoints. A custodian can list their Silicons’ subscriptions.
Viewers and incoming grants GET or POST /viewers, DELETE /viewers/{viewer} Signed-in accounts can inspect their grants. Owner or custodian grants or revokes access.
Allow sharing from another account GET or POST /allowed-accounts, DELETE /allowed-accounts/{account} Owner or custodian. For a custodian, supply the target silicon_id.
Manage test environments GET or POST /test-environments, GET or DELETE /test-environments/{id}, GET /test-environments/{id}/key, POST /test-environments/{id}/key-rotations or /restorations Signed-in account creates its own environment. Owner manages lifecycle. Its custodian circle can inspect the environment and key.
Use an isolated environment Send X-Remind-Test-Key on data calls. GET /testing-environment and POST /testing-environment/cleanings take the key alone. Holder of the environment key. Normal data routes also require the access token.
Report an integration problem POST /reports with {message,pr} and an idempotency key, GET /reports/{id} Reporting account. Include the request ID. A test environment simulates reports.

Production has retired test environments. Hide their controls when GET /api/versions returns features.test_environments: false. The test routes in the table are available on deployments with a testing database. Discovery also reports features.ting and features.reports.

See the HTTP reference for query parameters, examples and payloads for each feature, and the testing guide for lifecycle and limits.

Receiving due reminders#

Production enrolls the Silicon when it first opens GET /auth/me or creates a reminder. A successful enrollment is recorded once. GET /ting returns configured, simulated and registered_at (the last successful registration). If registration was unavailable, retry with PUT /ting. Use that same operation when the Silicon chooses to reconnect after revoking its subscription in Ting. The recipient controls silent delivery, blocking and subscriptions in Ting.

At the due time, Remind sends remind.reminderDue to the owner’s immutable UUID. The Ting’s data contains the execution ID, schedule ID, reminder text, scheduled UTC instant and IANA timezone. Adding a webhook is optional. Each configured endpoint receives a copy with the same execution ID. Ting and webhook results are recorded independently. ting_status: accepted means Ting accepted the notification. blocked records a recipient preference. unsubscribed indicates an absent grant. webhook_status: none means there were no endpoints. untracked identifies earlier history. Test environments simulate Ting without contacting the recipient. Read execution history for the durable outcome. A frontend can poll it using the page cursor when traversing older results, and refresh the first page for new occurrences. Webhook format and signature verification

Pagination, retries and errors#

  • Lists return items and next_cursor. For reminders and history pass that cursor as cursor, preserving all filters. For visible Silicons and test environments pass it as after. A null cursor ends the list. Page sizes are 1–100 where limit is accepted.
  • Create, edit and bulk-update reminders and submit reports with an Idempotency-Key of 16–255 visible ASCII characters. Reuse the same key and body after a timeout. A different body with that key returns 409. For a webhook creation or an environment mutation with an uncertain result, read the current state before repeating it.
  • The API admits up to 300 authenticated requests per account per minute per API process. Directory resolution has a separate budget of 30 per account per minute. Reports allow 10 per hour. On 429, honor Retry-After when present. On 503, back off and retry using the original mutation key.
  • Every bearer request checks the signature, audience, issuer and validity interval and requires live Accounts introspection for an active access_token belonging to remind. On 401, reacquire the app token through the interface’s Accounts session or offer sign-in. On 403, keep the operation unavailable. A private reminder outside the caller’s view returns 404. 422 indicates invalid input. Read error.code, error.message, optional error.hint and error.request_id when displaying or reporting failures.